TinyML Based Point of Care Device Development Using 8-bit Microcontroller for accurate Water Quality Measurement
编号:97 访问权限:仅限参会人 更新:2026-11-13 12:22:43 浏览:10次 Online

报告开始:2026年11月21日 13:15(Asia/Kolkata)

报告时间:15min

所在会场:[S2] Internet of Things and Intelligent Sensing Systems [S2-2] Internet of Things and Intelligent Sensing Systems

视频 无权播放 演示文件 附属文件

提示:该报告下的文件权限为仅限参会人,您尚未登录,暂时无法查看。

摘要
Accurate determination of pH is a critical requirement for water-quality monitoring in aquaculture; yet the deployment of machine learning algorithms on 8-bit microcontrollers is severely constrained by their minute memory and computational capabilities. This work reports a proof-of-concept point-of-care device for pH-estimation based on an electrochemical pH sensor with two-stage operational amplifier-based signal-conditioning circuit: low-pass filtering and temperature compensation, a lookup-table-assisted calibration model implemented on a low-power 8-bit AVR microcontroller (ATmega328P, 32 KB flash, 2 KB SRAM, 16 MHz, no floating-point unit) as well as associated mobile application for real-time visualization and alarms. Four compact machine learning models were evaluated on the target microcontroller after aggressive weight pruning and 8-bit integer quantization: a two-hidden-layer feed-forward neural network, Bonsai framework, a Tiny1D CNN and a Linear SVM. The Linear SVM algorithm demonstrated the best performance with 98.0% accuracy, 0.08 pH mean absolute error, 0.11 pH root-mean-square error, and 0.99 coefficient of determination (R²), while requiring only 1.0 KB flash memory, 36 B SRAM and 8 ms per inference. The Tiny1D CNN model achieved 91.2% accuracy but with increased resource requirements (1.8 KB flash, 158 B SRAM, 45 ms). These results confirm that computationally intensive machine learning algorithms can be successfully deployed in aquaculture pH-sensing applications with ubiquitous 8-bit microcontrollers. The proposed approach will be further validated in field conditions in brackish-water aquaculture, with long-term drift assessment and power-consumption characterization as the follow-up studies.
关键词
pH sensing;TinyML;ATmega328P;quantization;water-quality monitoring;point-of-care device;aquaculture
报告人
Menaka M
Research Scholar Vel tech University

Menaka M, is currently pursuing her Ph.D. in the Department of Computer Science and Engineering at Vel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology, Chennai. Previously, she worked as Developer in Code Mantra, Vellore. She completed her B.E in Electronics and Communication Engineering, and her M.E in Embedded System and Technologies in Anna University, Chennai. Her research interests include Machine Learning and IoT.

稿件作者
Menaka M Vel tech University
Dhilipkumar V Veltech university
Kanagachidambaresan G R BITS Pilani, K K Birla Goa Campus
发表评论
验证码 看不清楚,更换一张
全部评论
重要日期
  • 会议日期

    11月20日

    2026

    至

    11月22日

    2026

  • 10月31日 2026

    初稿截稿日期

  • 11月07日 2026

    提前注册日期

  • 11月22日 2026

    注册截止日期

主办单位
United Societies of Science
承办单位
Pondicherry University
协办单位
IEEE Section
IEEE Madras Section
移动端
在手机上打开
小程序
打开微信小程序
客服
扫码或点此咨询